On the Park Main Page
  Site Plan
  The Arbutus
     The Monterey
  Specifications
      Contact & Sales
      PDF Brochure












 




SOLD OUT

SPECIFICATIONS


FOUNDATION

• Reinforced concrete foundation walls
• Engineered walls where required
________________________________________________________

FRAMING

FLOOR
• 2x10 floor joists
• 2x2 cross bridging
• 5/8” T&G sheathing glued and screwed
• Wood beams-4ply 2x10 kiln dried or manufactured beams as required

EXTERIOR WALLS
• 2x6 construction grade spruce
• 16” o.c.; double top plate, single bottom plate
• 7/16” sheathing
• 2x10 window and door headers

INTERIOR WALLS
• 2x4 construction grade spruce 16” o.c.; double top plate, single bottom plate

ROOF
• Manufactured trusses 24” o.c.
• 7/16” OSB sheathing w/clips
________________________________________________________


ELECTRICAL

• 100 amp service panel
• Designer selected light fixture package
• All plugs, switches & lights as per code
• Decora switches

________________________________________________________

EXTERIOR FINISH

ROOF
• 35yr fiberglass shingles
• Domed vents and metal flashing
• Continuous eavestrough with downspouts
• Pre-finished metal soffits venting to attic

SIDING
• Hardipanel accents where applicable
• Vinyl siding
• Veneered rock accents where applicable

DECKS
• Vinyl deck covering
• Aluminum railings
________________________________________________________

WINDOWS & EXTERIOR DOORS

WINDOWS P.V.C
• Double glazed white vinyl windows
• Casements or sliders as per plan

DOORS
• Front insulated metal door. Security viewer supplied for solid front doors. Rear/side unit insulated metal door. Glazed lites as per plan. All doors include dead bolt assemblies.
________________________________________________________

PLUMBING

• 1 piece molded bathtubs as per plan
• 1 piece molded shower with chrome door as per plan
• Ventilation fan as per CNA/CSA-F326 to be installed by heating contractor
• Moen single lever chrome taps
• Ventilation system rough in as per CNA/CSA-F326
• All drains and water lines to code.
________________________________________________________

MECHANICAL

• Electric baseboard radiant heat
• 40 gallon water heater – electric
• Napolean direct vent gas fireplace or equivalent
________________________________________________________

INSULATION

• As per code R20 walls and R40 ceiling
• 6 mil GSB poly, continuous seal on all
________________________________________________________

WALLBOARD

• 1/2” Drywall supplied for walls and 5/8” drywall or HD drywall and strapping for ceiling
• Taped and filled
• Green board for shower areas 5/8” fire rated where required
________________________________________________________

INTERIOR FINISH

CLOSET
• Closet shelves, rods, hardware

INTERIOR DOORS
• Pre-hung, embossed, primed paneled swing doors complete with jamb and stop. Matching paneled bifold doors for closets.

TRIM
• MDF baseboards and MDF casings where applicable.

HARDWARE
• High quality locks
• Chrome paper holders, towel bars & mirrors in all baths.

KITCHEN CABINETS
• Raised panel white cabinets
• Laminate countertops

INTERIOR PAINT
• Walls primed and painted - 2 coats
• Ceilings textured except in bathroom and kitchen area
• Trim-primed and painted - 2 coats

FLOORING
• Quality carpet / vinyl / laminate flooring as per plan
________________________________________________________

GARAGE

• Insulated and drywalled
• Insulated steel door
________________________________________________________

DRIVEWAY

• 3/8 exposed aggregate concrete driveway

________________________________________________________

LANDSCAPING

• Fully landscaped as per landscape plan


The information on these properties has been prepared from building and site